This is a mirror of the original site (arm.jonpalmisc.com), which was taken down.
Hosted on IPFS, storage on Filebase.
Compare unsigned lower than or same as immediate and fault
This instruction compares the unsigned value in a register with an immediate, and generates a Conditional fault exception if the register value is lower than or the same as the immediate. If an exception is generated, the <reason> operand is copied to ESR_ELx.
This instruction does not affect the condition flags.
This is a pseudo-instruction of CFLT<cc> (immediate). This means:
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| sf | 1 | 1 | 1 | 0 | 1 | 1 | 0 | 0 | 1 | 1 | imm9h | 0 | 0 | 0 | 0 | imm2 | 0 | imm9l | Rt | ||||||||||||
| cc | |||||||||||||||||||||||||||||||
| <reason> |
Is a 2-bit unsigned immediate, in the range 0 to 3, encoded in the "imm2" field. |
| <Wt> |
Is the 32-bit name of the general-purpose register to be tested, encoded in the "Rt" field. |
| <imms1> |
Is a signed immediate, in the range -1 to 510, encoded as "imm9h:imm9l" minus 1. |
| <Xt> |
Is the 64-bit name of the general-purpose register to be tested, encoded in the "Rt" field. |
The description of CFLT<cc> (immediate) gives the operational pseudocode for this instruction.
Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.