This is a mirror of the original site (arm.jonpalmisc.com), which was taken down.
Hosted on IPFS, storage on Filebase.
Generic Interrupt Controller synchronization barrier
This instruction provides explicit synchronization mechanisms for GIC and GICR System instructions.
This is an alias of SYS. This means:
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| 1 | 1 | 0 | 1 | 0 | 1 | 0 | 1 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | op2 | Rt | ||||||
| L | op1 | CRn | CRm | ||||||||||||||||||||||||||||
GSB <gsb_op>
is equivalent to
SYS #0, C12, C0, #<op2>{, <Xt>}
and is the preferred disassembly when SysOp('000', '1100', '0000', op2) == Sys_GSB.
The description of SYS gives the operational pseudocode for this instruction.
Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.
This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.