This is a mirror of the original site (arm.jonpalmisc.com), which was taken down.
Hosted on IPFS, storage on Filebase.
Trace Synchronization Period Register
Controls how often trace protocol synchronization requests occur.
External register TRCSYNCPR bits [31:0] are architecturally mapped to AArch64 System register TRCSYNCPR[31:0].
This register is present only when FEAT_ETE is implemented and FEAT_TRC_EXT is implemented. Otherwise, direct accesses to TRCSYNCPR are RES0.
TRCSYNCPR is a 32-bit register.
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RES0 | PERIOD | ||||||||||||||||||||||||||||||
Reserved, RES0.
Defines the number of bytes of trace between each periodic trace protocol synchronization request.
| PERIOD | Meaning |
|---|---|
| 0b00000 |
Trace protocol synchronization is disabled. |
| 0b01000 |
Trace protocol synchronization request occurs after 28 bytes of trace. |
| 0b01001 |
Trace protocol synchronization request occurs after 29 bytes of trace. |
| 0b01010 |
Trace protocol synchronization request occurs after 210 bytes of trace. |
| 0b01011 |
Trace protocol synchronization request occurs after 211 bytes of trace. |
| 0b01100 |
Trace protocol synchronization request occurs after 212 bytes of trace. |
| 0b01101 |
Trace protocol synchronization request occurs after 213 bytes of trace. |
| 0b01110 |
Trace protocol synchronization request occurs after 214 bytes of trace. |
| 0b01111 |
Trace protocol synchronization request occurs after 215 bytes of trace. |
| 0b10000 |
Trace protocol synchronization request occurs after 216 bytes of trace. |
| 0b10001 |
Trace protocol synchronization request occurs after 217 bytes of trace. |
| 0b10010 |
Trace protocol synchronization request occurs after 218 bytes of trace. |
| 0b10011 |
Trace protocol synchronization request occurs after 219 bytes of trace. |
| 0b10100 |
Trace protocol synchronization request occurs after 220 bytes of trace. |
Other values are reserved. If a reserved value is programmed into PERIOD, then the behavior of the synchronization period counter is CONSTRAINED UNPREDICTABLE and one of the following behaviors occurs:
The reset behavior of this field is:
Must be programmed if TRCIDR3.SYNCPR == 0.
If the trace unit is not in the Idle state it is CONSTRAINED UNPREDICTABLE whether writes to this register are ignored.
| Component | Offset | Instance |
|---|---|---|
| ETE | 0x034 | TRCSYNCPR |
Accessible as follows:
Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.
This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.